Description: Normal 0 7.8 磅 0 2 false false false EN-US ZH-CN X-NONE Hantek Digital LCR Meter hantek1832C Hantek1833C Handheld Portable Inductance Capacitance and Resistance Measuring Tester Tools Language: English Hantek 1832C/Hantek 1833C handheld LCR is a portable handheld measuring instrument to measure the parameters of the component such as inductance、capacitance、resistance and so on. Small volume,powered by 5V lithium battery,it can meet the requirements of desktop LCR application, and can also be applied to flow measurement and handheld measurement. Feature: -100Hz、120Hz、400Hz、1kHz、4kHz、10kHz、40kHz、50kHz、75kHz、100kHz 10 typical test frequency (Hantek1832C)7 typical test frequency -2.8 inch TFT LCD,Switch between Chinese and English -HD display,dual display of measurement data,the result is clear -Support data record analysis -Support PC upper computer,easy to control and measure remotely -Test lead:3 end/5 end switch -Measuring speed:high speed/intermediate speed/low speed switch -Range:support manual/auto switch,easy to do quick measurement -LCR adopted rechargeable design,Large capacity lithium battery,super standby -Double shock protection sleeve,all-round protection,shakeproof,fall-arrest,protect -the machine from damage,longer use time, more comfortable measurement -Bracket design,easy to put and measure -LCR high precision test instrument Specification: Model Hantek1832C Hantek1833C Test frequency 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz 100Hz, 120Hz, 400Hz, 1kHz, 4kHz, 10kHz, 40kHz, 50kHz, 75kHz, 100kHz Accuracy 0.30% Equivalent Circuit series, parallel Test level 0.6Vrms 0.6Vrms, 0.3Vrms Measurement way manual, auto Display screen 2.8 inch TFT LCD Measurement parameters principle parameter: L/C/R/Z deputy parameter: X/D/Q/θ/ESR Principle parameter L/C/R/Z Deputy parameter X/D/Q/θ/ESR Inductance Measurement range (L) 0-2000H Capacitance Measurement range (C) 0-20mF Resistance Measurement range (R) 0-20MΩ Measurement speed high speed(4 times/s), intermediate speed(twice/s), low speed(once/s) Reset function open circuit calibration, short-circuit calibration Test terminal configuration 3 termianl, 5 terminal General feature standard with 1.Type-C data cable; 2.power adapte; 3.short circuit card; 4.red and black rubber plug; 5.large capacity lithium battery Capacitance C and dissipationD 100Hz/120Hz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 20mF 4.000mF~20.000mF 8.00%+5 digits 0.08 series 4mF 400.0μF~3.9999mF 2.00%+3 digits 0.02 series 400μF 40.00μF~399.99μF 0.60%+2 digits 0.006 series 40μF 4.000μF~39.999μF 0.40%+2 digits 0.004 series 4μF 400.0nF~3.9999μF 0.40%+2 digits 0.004 ---- 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 parallel 40nF 4.000nF~39.999nF 0.5%+3 digits 0.005 parallel 4nF 0pF~3.999nF 1.5%+5 digits ------ parallel 1KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 1000uF 400.0uF~999.9uF 3.00%+5 digits 0.03 series 400μF 40.00μF~399.99μF 1.50%+3 digits 0.015 series 40μF 4.000μF~39.999μF 0.60%+2 digits 0.006 series 4μF 400.0nF~3.9999μF 0.40%+2 digits 0.004 ---- 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 parallel 40nF 4.000nF~39.999nF 0.6%+3 digits 0.006 parallel 4nF 400.0pF~3.9999nF 0.6%+3 digits 0.006 parallel 400pF 0.0pF~399.9pF 3%+5 digits ------ parallel 10KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 100μF 40.00μF~100.00μF 4.00%+5 digits 0.04 series 40μF 4.000μF~39.999μF 2.0%+3 digits 0.02 series 4μF 400.0nF~3.9999μF 0.60%+2 digits 0.006 series 400nF 40.00nF~399.99nF 0.4%+2 digits 0.004 series 40nF 4.000nF~39.999nF 0.4%+2 digits 0.004 ------ 4nF 400.0pF~3.9999nF 0.4%+2 digits 0.004 parallel 400pF 40.00pF~399.99pF 0.6%+3 digits 0.006 parallel 40pF 0.00pF~39.99pF 2.5%+5 digits ------ parallel 40KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 100μF 40.00μF~100.00μF 6.00%+5 digits 0.06 series 40μF 4.000μF~39.999μF 4.0%+3 digits 0.04 series 4μF 400.0nF~3.9999μF 1.0%+2 digits 0.01 series 400nF 40.00nF~399.99nF 0.6%+2 digits 0.006 series 40nF 4.000nF~39.999nF 0.6%+2 digits 0.006 ------ 4nF 400.0pF~3.9999nF 0.6%+2 digits 0.006 parallel 400pF 40.00pF~399.99pF 1%+3 digits 0.01 parallel 40pF 0.000pF~39.999pF 3%+5 digits ------ parallel 100KHz Range Display range Accuracy Ce Accuracy De Recommended equivalent mode 10μF 4.000μF~10.000μF 8.0%+20 digits 0.08 series 4μF 400.0nF~3.9999μF 5.0%+10 digits 0.05 series 400nF 40.00nF~399.99nF 1.5%+5 digits 0.015 series 40nF 4.000nF~39.999nF 1%+2 digits 0.01 series 4nF 400.0pF~3.999nF 1%+2 digits 0.01 ------ 400pF 40.00pF~399.99pF 1.5%+2 digits 0.015 parallel 40pF 4.000pF~39.999pF 2%+5 digits 0.02 parallel 4pF 0.000pF~3.999pF 5%+10 digits ------ parallel Inductance L and quality factor 100Hz/120Hz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1000H 400.0H~999.9H 2.00%+3 digits 0.02 parallel 400H 40.000H~399.99H 0.60%+2 digits 0.006 parallel 40H 4.000H~39.999H 0.40%+2 digits 0.004 parallel 4H 400.0mH~3.9999H 0.40%+2 digits 0.004 ---- 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 series 40mH 4.000mH~39.999mH 0.6%+3 digits 0.006 series 4mH 0uH~3.999mH 3.0%+5 digits ------ series 1kHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1H 400.0mH~999.9mH 1.50%+3 digits 0.015 parallel 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 parallel 40mH 4.000mH~39.999mH 0.4%+2 digits 0.004 ------ 4mH 400.0uH~3.9999mH 0.4%+2 digits 0.004 series 400uH 40.00uH~399.99uH 0.8%+3 digits 0.008 series 40uH 0.00uH~39.99uH 3.0%+5 digits ------ series 10kHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 100H 40.00H~100.00H 2.0%+3 digits 0.02 parallel 40H 4.000H~39.999H 0.60%+2 digits 0.006 parallel 4H 400.0mH~3.9999H 0.40%+2 digits 0.004 parallel 400mH 40.00mH~399.99mH 0.4%+2 digits 0.004 ------ 40mH 4.000mH~39.999mH 0.4%+2 digits 0.004 series 4mH 400.0uH~3.9999mH 1%+3 digits 0.01 series 400uH 0.0uH~399.9uH 3.0%+5 digits ------ series 40kHz Range Display range Accuracy Le Accuracy De* Recommended equivalent mode 1H 400.0mH~999.9mH 2.0%+4 digits 0.02 parallel 400mH 40.00mH~399.99mH 0.8%+2 digits 0.008 parallel 40mH 4.000mH~39.999mH 0.8%+2 digits 0.008 ------ 4mH 400.0uH~3.9999mH 0.8%+2 digits 0.008 series 400uH 40.00uH~399.99uH 1.5%+3 digits 0.015 series 40uH 0.000uH~39.999uH 4.0%+5 digits ------ series 100kHz Range Display range Accuracy Le Accuracy De Recommended equivalent mode 100mH 40.00mH~399.99mH 2.5%+2 digits 0.025 parallel 40mH 4.000mH~39.999mH 1.5%+2 digits 0.015 parallel 4mH 400.0uH~3.9999mH 1.0%+2 digits 0.01 ------ 400uH 40.00uH~399.99uH 1.0%+2 digits 0.01 series 40uH 4.000uH~39.999uH 1.5%+5 digits 0.015 series 4uH 0.000uH~3.999uH 4%+10 digits ------ series Impedance Z and phase angle 100Hz, 120Hz, 1kHz, 10kHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 3.0%+10 digits 3.4° parallel 4MΩ 400.0kΩ~3.9999MΩ 1.2%+3 digits 0.7° parallel 400kΩ 40.00kΩ~399.99kΩ 0.3%+3 digits 0.2° parallel 40kΩ 4.000kΩ~39.999kΩ 0.25%+2 digits 0.1° ------ 4kΩ 400.0Ω~3.9999kΩ 0.25%+2 digits 0.1° series 400Ω 40.00Ω~399.99Ω 0.25%+2 digits 0.1° series 40Ω 4.000Ω~39.999Ω 0.5%+3 digits 0.3° series 4Ω 0.4000Ω~3.9999Ω 2.0%+3 digits 1.1° series 0.4Ω 0.0000Ω~0.3999Ω 4.0%+3 digits ------ series 40kHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 7.0%+41 digits 4.0° parallel 4MΩ 400.0kΩ~3.9999MΩ 2.5%+3 digits 1.4° parallel 400kΩ 40.00kΩ~399.99kΩ 1.0%+4 digits 0.6° parallel 40kΩ 4.000kΩ~39.999kΩ 1.0%+4 digits 0.6° ------ 4kΩ 400.0Ω~3.9999kΩ 0.5%+3 digits 0.3° series 400Ω 40.00Ω~399.99Ω 0.5%+3 digits 0.3° series 40Ω 4.000Ω~39.999Ω 0.7%+4 digits 0.4° series 4Ω 0.4000Ω~3.9999Ω 2.0%+6 digits 1.1° series 0.4Ω 0.0000Ω~0.3999Ω 5.0%+10 digits ------ series 100kHz Range Display range Accuracy Ze Accuracy Recommended equivalent mode 20MΩ 4.000MΩ~20.000MΩ 9.0%+20 digits 5.2° parallel 4MΩ 400.0kΩ~3.9999MΩ 4.0%+10 digits 2.3° parallel 400kΩ 40.00kΩ~399.99kΩ 1.5%+4 digits 0.9° parallel 40kΩ 4.000kΩ~39.999kΩ 1.0%+2 digits 0.6° parallel 4kΩ 400.0Ω~3.9999kΩ 0.7%+2 digits 0.4° ------ 400Ω 40.00Ω~399.99Ω 0.7%+2 digits 0.4° series 40Ω 4.000Ω~39.999Ω 1.0%+5 digits 0.6° series 4Ω 0.4000Ω~3.9999Ω 3.0%+10 digits 1.7° series 0.4Ω 0.0000Ω~0.3999Ω 7%+20 digits ------ Package: 1 x LCR meter 1 x power charger 1 x usb cable 1 x pair test lead 1 x pair WOSONTEL clip Function Display
Price: 134.49 USD
Location: SZ,GD
End Time: 2024-02-13T03:46:58.000Z
Shipping Cost: 20 USD
Product Images
Item Specifics
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 14 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Brand: Hantek
Form Factor: Handheld
Frequency Range: 100Hz、120Hz、400Hz、1kHz、4kHz、10kHz、40kHz、50kHz、75kH
Unit Type: Unit
Measurement Functions: L, C, R, D, Q, θ, X
Product: LCR Meter
MPN: 1832C/1833C
Country/Region of Manufacture: China
Available Variations
Color: Hantek 1832C
Price: 134.49 USD
Available Quantity: 10
Quantity Sold: 0
Color: Hantek 1833C
Price: 168.1 USD
Available Quantity: 10
Quantity Sold: 0